Standard
|
:
|
Acc.to VDE 0815 & TS 13767
|
Conductor resis. (loop)
|
:
|
Max. 130 Ω/km : Ø 0,60 mm
Max. 73,2 Ω/km : Ø 0,80 mm
|
Insulation resistance
|
:
|
Min. 100 MΩ.km
|
Mutual capacitance
|
:
|
Max. 1001) nF/km
|
Capacity Unbalanced (k)
|
:
|
Max. 3002) pF/100 m
|
Operating voltage
|
:
|
Max. 3003) V
|
Test voltage (AC 50 Hz)
|
:
|
Core/core : 800 V
Core/screen : 800 V
|
Temperature range
|
:
|
Fixed : - 30 oC ~ + 70 oC
Installation : - 5 oC ~ + 50 oC
|
Min. bending radius
|
:
|
10 x D
|
Flame retardance test
|
:
|
EN 60332-1-2 & IEC 60332-1-2
|
Oil resistant test
|
:
|
Acc. to EN 60811-404, & IEC 60811-404
EN 50290-2-22/TM54; 4 hours @70oC
|
1) This value may be exceeded by 20% by cables with up to 4 pairs
2) 20% of the values, at least one value up to 400 pF permitted
3) up to 600V permissible for short periods (6 s/min)
|
: Conform to 2014/35/EU (Low Voltage Directive)
Conform to 2011/65/EU & 2015/863 (RoHS Directives)
|